page 133
Function
TDM_WRITE_INTERN
Library
TDM.LIB
Function symbol
Purpose
The function writes an internal variable to the tdm R 360.
Parameter
Function inputs
Function
outputs
Description
As opposed to the variables which are processed and
generated in the controller as target and preset values and are
automatically updated by the operating system of the units, the
internal tdm variables (e.g. clock or values saved in the tdm R
360) cannot be 'automatically' read and written.
Just like any other variable an internal variable has to be
identified to TDM_CONFIG of the application software. The
following read process is executed once by calling the function
TDM_WRITE_INTERN. The function input ENABLE can block
the execution.
HANDLE is allocated the defined number of the internal variable
from the tdm R 360. A handle number must only be allocated
once in the tdm R 360 as well as in the application software.
RESULT = TRUE shows if the handle stated when calling the
function has been found.
The programmer himself has to ensure the administration of
internal data in the controller by means of suitable software
routines. A changed internal variable is not automatically
transferred to the DISPLAY, but only when called for via
TDM_WRITE_INTERN.
Name
Data type
Description
ENABLE
BOOL
TRUE:
function is executed
FALSE: function is not executed
HANDLE
WORD
designation (number) of the internal variable
in the tdm
Name
Data type
Description
RESULT
BOOL
TRUE:
HANDLE was found (was defined)
Содержание ecomat 100 R 360 Series
Страница 1: ...System manual ecomat 100 type R 360 ...
Страница 14: ...page 14 ...
Страница 26: ...page 26 ...
Страница 86: ...page 86 ...
Страница 100: ...page 100 ...
Страница 126: ...page 126 ...
Страница 146: ...page 146 ...
Страница 162: ...page 162 ...
Страница 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Страница 164: ...page 164 Annex 2 2 Type CR0016 ...
Страница 165: ...page 165 Annex 2 3 Type CR0017 ...
Страница 166: ...page 166 Annex 2 4 Type CR0501 ...