page 144
11.4. Unit control
Function
TDM_PARAM
Library
TDM.LIB
Function symbol
Purpose
The function monitors and transfers the unit parameters to the
basic setting of the display.
Parameter
Function inputs
Function outputs, none
Description
The function TDM_PARAM should only be called to set new unit
parameters. With TDM_PARAM you can e.g. change the
brightness, the softkey mask or the scroll time for the
messages.
For the individual values please refer to the tdm R 360 manual.
Name
Data type
Description
ENABLE
BOOL
TRUE:
function is executed
FALSE: function is not executed
PA
BYTE
parameter code
VALUE
BYTE
additional value, to be stated depending
on the parameter code