Function
TDM_REQUEST_STATUS
Library
TDM.LIB
Function symbol
Purpose
The function requests the current status report of the tdm R
360.
Parameter
Function input
Function outputs, none
Description
The status report provides the application software with all the
relevant unit information:
•
currently displayed picture
•
currently displayed message
•
keyboard status (which key has been pressed or released)
•
LED is set or not set
•
unit status (e.g. preset value entry active)
•
status of the signal output (not CR1000)
TDM_REQUEST_STATUS requests a one-time status report
from the display. MODE defines which data are to be polled.
Like a one-shot display the status of the above points is
transferred to the controller.
The function has to be called again for each status report. To
block the execution of the function the input ENABLE can be set
to FALSE.
Name
Data type
Description
ENABLE
BOOL
TRUE:
function is executed
FALSE: function is not executed
MODE
BYTE
value for selecting the feedback parameters
Value
Output via
Description
0
TDM_REPORT_STATUS
unit status
1
TDM_REPORT_KEYDATA
keyboard status (keys 1-32)
2
TDM_REPORT_KEYDATA
keyboard status (keys 33-64)
3
TDM_REPORT_KEYDATA
LED status (keys 1-32)
4
TDM_REPORT_KEYDATA
LED status (keys 33-64)
5
TDM_REPORT_OUTPUT
status of signal output
Содержание ecomat 100 R 360 Series
Страница 1: ...System manual ecomat 100 type R 360 ...
Страница 14: ...page 14 ...
Страница 26: ...page 26 ...
Страница 86: ...page 86 ...
Страница 100: ...page 100 ...
Страница 126: ...page 126 ...
Страница 146: ...page 146 ...
Страница 162: ...page 162 ...
Страница 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Страница 164: ...page 164 Annex 2 2 Type CR0016 ...
Страница 165: ...page 165 Annex 2 3 Type CR0017 ...
Страница 166: ...page 166 Annex 2 4 Type CR0501 ...