66
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
ifm function elements
ifm function elements for the device CR0301
>
Parameters of the outputs
19810
Parameter
Data type
Description
DATA
ARRAY [0..7] OF BYTE
received data, (1...8 bytes)
DLC
BYTE
Number of the bytes of the CAN telegram read from the receive buffer
allowed: 0...8
RTR
BOOL = FALSE
Received message was a Remote Transmission Request
(wird hier nicht unterstützt)
AVAILABLE
BYTE
Number of the CAN telegrams received but not yet read from the
receive buffer (before the FB is called).
Possible values = 0...16
0 = no valid data available
OVERFLOW
BOOL
TRUE:
Overflow of the data buffer
loss of data!
FALSE:
Data buffer is without data loss
Содержание Ecomat 100 Mobile CR0301
Страница 209: ...209 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 210: ...210 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 211: ...211 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 212: ......