25
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
System description
Hardware description
>
3.2.7
Status LED
1437
The operating states are indicated by the integrated status LED (default setting).
LED colour
Display
Description
Off
Permanently off
No operating voltage
Orange
Briefly on
Initialisation or reset checks
(time frame = 200 ms)
Green
Flashing with 5 Hz
TEST=TRUE:
no runtime system loaded
(time frame = 200 ms)
Green
Flashing with 2 Hz
Application = RUN
(time frame = 200 ms)
Green
Permanently on
Application = STOP
Red
Flashing with 2 Hz
Application = RUN with error
(time frame = 200 ms)
Red
Briefly on
FATAL ERROR
(time frame = 200 ms)
Red
Permanently on
TEST=TRUE:
Application = STOP and FATAL ERROR
TEST=FALSE:
ERROR STOP / SYSTEM STOP
The status LED can be changed by the programming system for the operating states STOP and RUN.
To do so, the following system variable is used:
LED_MODE
Flashing frequency from the data structure "LED_MODES"
permissible: LED_2HZ, LED_1HZ, LED_05HZ, LED_0HZ (constant)
If the flashing mode is changed in the application program, the default setting table is no longer
valid.
Содержание Ecomat 100 Mobile CR0301
Страница 209: ...209 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 210: ...210 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 211: ...211 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 212: ......