119
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
ifm function elements
ifm function elements for the device CR0301
>
Parameters of the inputs
20089
Parameter
Data type
Description
ENABLE
BOOL
TRUE (only for 1 cycle):
initialisation of the function block
FALSE:
unit is not executed
CHANNEL
BYTE
Number of the interrupt input
0...3 for the inputs IN08...IN11
MODE
BYTE
Type of edge at the input CHANNEL which triggers the interrupt
1 = rising edge (standard value)
2 = falling edge
3 = rising and falling edge
> 3 = standard value
READ_INPUTS
BOOL
TRUE:
read the inputs 8...11 before calling the program
and write to the input flags IN08...IN11
FALSE:
only read the channel indicated under CHANNEL
and write to the corresponding input flag INnn
WRITE_OUTPUTS
BOOL
TRUE:
write the current values of the output flags Q00...Q03
to the outputs after completion of the program sequence
FALSE:
do not write outputs
ANALOG_INPUTS
BOOL
TRUE:
read inputs 16...23 and write the unfiltered,
uncalibrated analogue values to the flags
ANALOG_IRQ16...23
FALSE:
do not write the flags A_IN16...23