154
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
ifm function elements
ifm function elements for the device CR0301
>
Parameters of the inputs
355
Parameter
Data type
Description
X
WORD
input value
XS
WORD
preset value
XMAX
WORD
maximum preset value
KP
BYTE
proportional component of the output signal
KI
BYTE
integral component of the output signal
KD
BYTE
differential component of the output signal
>
Parameters of the outputs
356
Parameter
Data type
Description
Y
WORD
Manipulated variable (0...1000 ‰)
>
Recommended settings
357
KP = 50
KI = 30
KD = 5
With the values indicated above the controller operates very quickly and in a stable way. The controller
does not fluctuate with this setting.
► To optimise the controller, the values can be gradually changed afterwards.
Содержание Ecomat 100 Mobile CR0301
Страница 209: ...209 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 210: ...210 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 211: ...211 ifm Programming Manual ecomatmobile CabinetController CR0301 Runtime System V05 2016 04 21 Notizen Notes Notes ...
Страница 212: ......