ifm function elements
ifm function elements for the device CR0301
>
Parameters of the inputs
535
Parameter
Data type
Description
X1
WORD
actual value channel 1
X2
WORD
actual value channel 2
XS
WORD
preset value
XMAX
WORD
maximum preset value
KP
Byte
constant of the proportional component (/10)
(positive values only!)
TN
TIME
integral action time (integral component)
KD
BYTE
differential component (/10)
(positive values only!)
TV
TIME
derivative action time (differential component)
RESET
BOOL
TRUE:
reset the function element
FALSE:
function element is not executed
>
Parameters of the outputs
536
Parameter
Data type
Description
Y1
WORD
manipulated variable channel 1
Y2
WORD
manipulated variable channel 2