31
1693 RLC Digibridge
Operation
3.2.15 Connection to the 1433
Decade Resistor
Note:
The procedure for connecting the HARS-X
High-Accuracy Resistance Substituter is exactly the
same.
Connection to the 1433 or HARS Decade Resistors
can be accomplished using the 1657-9600 Extender
cables or 7000-04 Alligator Clip Leads.
The connection via the 7000-04 cable is shown in
Figure 3-26. When using 7000-04 Alligator Clip
Leads the alligator clips should be removed. The
simplest connection is a two-terminal measurement
on the 1433/HARS with ground strap connected be-
tween
LOW
and
GND
. But to minimize the noise
from the resistor decade, a three-terminal connection
might be preferable. The three-terminal connection
may be implemented by removing the ground strap
and attaching a separate lead between
GND
and
Digibridge chassis ground.
The connection via the 1657-9600 Extender Cable is
shown in Figure 3-27. It is for a three-terminal mea-
surement on the 1433/HARS with ground strap
not
connected between
LOW
and
GND
. The green guard
lead is used in this measurement to minimize noise.
Open and Short compensation should be performed
as described. Set the Digibridge to the required fre-
quency. Open compensation should be performed
as normal with the red pair and black pair separated
by at least 6 inches. Short compensation should be
performed as follows:
1. Connect the cables to the 1433/HARS as
shown.
2. Set the 1433/HARS to zero ohms.
3. Perform short on the Digibridge.
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
0 1
2
3
4
5
67
8
9
10
formerly made by GenRad
1433-33 10 MΩ DECADE RESISTOR
1 Ω STEPS
10 Ω STEPS
100 Ω STEPS
1 kΩ STEPS
10 kΩ STEPS
100 kΩ STEPS
1 MΩ STEPS
1693 RLC DigiBridge
TM
20.000
.0002
POWER
uF
I
L
P
H
P
L
I
H
mH
pF
nF
H
k
S
DEG
NOT 1kHz
RANGE HELD
CONST V.
PPM
START
NO GO
GO
BIAS
ON
EXTERNAL
BIAS
REMOTE
CONTROL
On
Off
SER
On
Off
CONST I.
RATIO
mS
uS
R
C
L
Y
Z
G
R
D
Q
ANG
B
X
R/Q
C/R
C/D
L/Q
PAR
IH
PH
IL
PL
IL
PL
PH
IH
Figure 3-26: Connection to 1433 via 7000-04 cable
Содержание RLC Digibridge 1693
Страница 12: ...x Table of Contents 1693 RLC Digibridge This page is intentionally left blank...
Страница 24: ...xxii 1693 RLC Digibridge Abbreviated Specifications This page is intentionally left blank...
Страница 122: ...98 1693 RLC Digibridge Operation Table 3 28 Truth table of compacted binary format for output data...
Страница 130: ...106 1693 RLC Digibridge Theory Figure 4 1 Block diagram of the 1693 RLC Digibridge...
Страница 163: ...139 1693 RLC Digibridge Service and Maintenance Table 5 11 Entry of limits Table 5 12 Bin assignment check...
Страница 171: ......