Trip Zone
•
No.
: Select which cameras to apply Trip Zone to.
•
Sensitivity
: Set daytime and nighttime sensitivity
settings between 1 (Low) and 5 (High).
•
Zone
: Define the motion detection block.
Use the remote control's arrow buttons to move the
block selection window up, down, left, and right. The
selection window consists of 8 blocks per row. Select/
deselect individual blocks using the
Camera
buttons.
You can use the mouse to drag the zone and then
select, clear, or reverse the selection.
From the zone selection screen, press the
"
button
or right-click on the mouse to open up the Zone Setup
menu.
-
Select
: Confirm the block selection in the
selection window.
-
Clear
: Clear the block selection in the selection
window.
-
Reverse
: Clear the blocks selected within the
selection window and select all unselected blocks
within the selection window.
-
Select All
: Select all blocks.
-
Clear All
: Clear all block selections.
-
Reverse All
: Clear all selected blocks within the
screen and select all unselected blocks within the
screen.
-
Trip Direction
: Define in which direction
the motion has to occur in order for it to be
considered an event. Select In for movements
from outside the selection area in or Out for
movements from inside the selection area out.
-
OK
: Save the changes and exit the menu.
-
Cancel
: Exit the menu without saving the
changes.
•
Actions
: Specify which actions to take when Trip
Zone is detected.
-
Record
: Specify which cameras to begin linked
recording on when an event occurs. If the
schedule is set to Event or Time & Event mode,
the selected cameras will begin linked recording
when an event occurs.
-
Alarm-Out
: Designate event-triggered alarm-out
channels and beeps.
-
Notify
: Configure to be notified of events by
Mail, LAN1 through 5, SNS, Push, and/or Alert
Window.
In order to use the Callback feature, the NVR must
be registered on the remote program.