![Idis DR-6100 Series Скачать руководство пользователя страница 48](http://html2.mh-extra.com/html/idis/dr-6100-series/dr-6100-series_operation-manual_3822433048.webp)
Part 3 - Configuration
48
Cameras do not feature built-in audio amplifier units
and therefore require the user to purchase a speaker
system with a built-in amplifier separately.
Upgrade
Select
Firmware Upgrade
to display the USB search
window.
Select the corresponding upgrade package from the
storage device connected to the NVR's USB port.
After selecting an upgrade package, select Apply to
upgrade the camera.
•
If an upgrade attempt fails, an upgrade failure
message will be displayed. Refer to
Error Code
Types on page 80
for more details.
•
The camera will reboot after the upgrade and then
reconnect automatically.
•
Current software version is not checked when
upgrading a network camera.
Record Setup
Refer to the
Menu Use on page 37
for basic
information on using the Setup menus.
General
Configure general recording settings.
•
Recycle
: When the recording disks become full,
the system overwrites existing data with new data,
starting with the oldest first. If
Recycle
is disabled,
recording will simply stop when the recording disks
reach their maximum capacity.
•
Event Record Dwell
: If linked recording is
designated as an event-triggered action, recording
takes place for the duration specified under this
setting. Select between 5 secs and 15 mins.
•
Auto Deletion
: Configure this option to delete
recording data automatically after the specified
number of days has elapsed. Select between 1 day
and 999 days.
To disable Auto Deletion, select
Never
. If enabled,
recording data will be stored on the NVR for
the specified number of days and then deleted
automatically. Expired recording data are deleted
automatically at midnight and will be deleted even if
the system reboots or the
Auto Deletion
setting has
been changed.