![Idex Hale Sam Скачать руководство пользователя страница 84](http://html2.mh-extra.com/html/idex/hale-sam/hale-sam_operation-installation-maintenance-manual_3699854084.webp)
68
ALWAYS FOLLOW PROPER OPERATING PROCEDURES. THE PUMP OPERATOR MUST BE
FAMILIAR WITH THE PUMP AND SAM OPERATING INSTRUCTIONS AS WELL AS OTHER
OPERATING GUIDELINES FOR THE APPARATUS AND ACCESSORIES.
NOTE
Any manual activation initiated by the operator cancels auto flow operations.
If supply hose is connected and hydrant is open, transition will begin. Otherwise connect hose,
open hydrant, then activate the hydrant intake by performing the following.
A.
On SAM Control Center, touch and drag corresponding intake button to the asso-
ciated target. See Figure 72.
Figure 72. Activating An Intake
NOTE
If intake is NOT adjacent to the SAM Control Center pressing the button on the MIV-
Auto placard (located at the intake) activates the intake as if swiping on the SAM Con-
trol Center.
B.
SAM Control Center displays VENTING while air bleeds from intake to onboard
water tank. See Figure 73. (Bleeding the air prevents the bulk of the air from en-
tering the pump.)
Figure 73. Activating A Hydrant Intake Sequence (Air Bleed)