98
6.3.3.4.5
Turning Off CAFS (When Activated With SAM)
When SAM activates CAFS, (via activating a Quickset or a preset) and then CAFS is turned off (via
the SAM Control Center) all open lines flow water only.
ACTIVATING A FOAM OFF BUTTON TURNS OFF THE SMARTCAFS SYSTEM, TURNING OFF
FOAM TO ALL FOAM CAPABLE DISCHARGES, HOWEVER, THE DISCHARGE(S) ARE NOT
CLOSED AND CONTINUE TO FLOW WATER ONLY.
NOTE
If the operator only touches and releases the button; a confirmation popup window
appears (Figure 117). Touch the YES button to close the line or the NO button to make
no change.
Figure 117. Foam Off Popup Confirmation
All discharges previously providing FOAM continue to provide water ONLY, until closed individu-
ally.
6.3.3.5
Exporting The Datalogger File
The SAM Control Center and the Pump Controller continuously stores data to a local data logger.
When directed by Hale, the current data log file may be copied from the SAM Control Center or
the Pump Controller to a USB memory stick (USB stick).
NOTE
USB memory stick requirements: USB 2.0, Formatted to FAT 32, and 16 Gigabytes
recommended.
6.3.3.5.1
Exporting The SAM Control Center Datalogger File
PERFORMING THIS PROCEDURE CAUSES SAM TO EXIT AUTO MODE.
When directed, perform the following to transfer the current data log to a USB stick.
A.
SAM Control Center, touch and hold system options button until loading icon
completes circle and Enter Password screen (Figure 22, page 24) is displayed.
B.
E
nter Configuration Mode password (see Table 6, page 50) as follows.
Sequentially, touch password digits.
Touch ENTER button.