![Idex Hale Sam Скачать руководство пользователя страница 35](http://html2.mh-extra.com/html/idex/hale-sam/hale-sam_operation-installation-maintenance-manual_3699854035.webp)
19
The tank-to-pump icon group provides manual control of the tank-to-pump valve, which controls
the flow of water from the onboard water tank to the pump. With SAM in Auto Mode, this valve is
controlled by the SAM system to prime the pump and provide an initial water supply for pumping
operations.
Figure 11. Manual Discharge Valve Control Icon Group
The SAM system provides one manual discharge valve control icon group for each discharge
valve. Each icon group manually controls the opening and/or closing of the valve for that dis-
charge. With SAM in Auto Mode, this valves function is automated to provide a consistent supply
of water including pressure regulation for pumping operations and this icon group is not visible.
Figure 12. Manual Intake Valve Control Icon Group
The SAM system provides one manual intake valve control icon group for each master intake
valve and Pony. Each icon group manually controls the opening and/or closing of that intake to
the pump. With SAM in Auto Mode, this valves function is automated to provide a smooth transi-
tion from the onboard water supply to an external water supply including automated air bleed (or
priming) for pumping operations and this icon group is not visible.
4.1.1.5
Engine Data Icon Group
The engine data screen displays multiple engine data icon groups (Figure 13) each identified by
a title and unit of measure text.
Figure 13. Engine Data Icon Group