6
PERFORMING THIS PROCEDURE CAUSES SAM TO EXIT AUTO MODE.
PUMP SEAL/PUMP SHAFT DAMAGE MAY OCCUR IF DRIP RATE IS LESS THAN ONCE
EVERY 6 SECONDS. THIS CONDITION DEGRADES PUMP PERFORMANCE.
SOME WATER ONLY OPERATIONS MAY DAMAGE THE CAFS SYSTEM IF THE CLUTCH IS
ENGAGED. REFERENCE CAFS QUICKSTART GUIDE, DISENGAGING THE COMPRESSOR
CLUTCH (PAGE 10 OF FSG-MNL-00176) TO ENSURE PROPER CAFS TURN OFF WHEN
SAM INCLUDES A CAFS SYSTEM.
THE CONTROLLER UNIT DEUTSCH CONNECTORS ARE KEYED TO PREVENT INTER-
CHANGE OR REVERSE DIRECTION INSERTION. DO NOT FORCE A CONNECTOR WITH-
OUT FIRST VERIFYING THE CONNECTORS ORIENTATION AND PLACEMENT.
THE SAM CONTROL CENTER WILL NOT FUNCTION PROPERLY WITHOUT ONE OF THE
DISPLAYS CONFIGURED AS THE MASTER.
THE STYLE 9327 NAVIGATOR MINI VALVE CONTROLLER DOES NOT SUPPORT PRES-
SURE INDICATION. DO NOT USE A STYLE 9327 NAVIGATOR MINI VALVE CONTROLLER
FOR DISCHARGE VALVE PURPOSES OR CALIBRATIONS.
TOUCH ONLY THE SPECIFIED BUTTON(S). FAILURE TO PERFORM THIS PROCEDURE
CORRECTLY MAY CAUSE SAM TO BECOME INOPERATIVE.
WHEN CLOSING AN INTAKE IN MANUAL MODE, ENSURE THE PUMP HAS AN ADEQUATE
WATER SUPPLY TO PREVENT OVERHEATING.
WHILE SAM CAN REDUCE PUMP OPERATOR WORKLOAD, IT DOES NOT TAKE THE
PLACE OF THE PUMP OPERATOR. THE PUMP OPERATOR STILL NEEDS TO CALCULATE
THE REQUIRED LINE PRESSURE TO SUPPORT THE HOSE LAY AND NOZZLE IN USE. SAM
WILL MAINTAIN THE SET PRESSURE IN AUTO MODE.
Содержание Hale Sam