![Idex Hale Sam Скачать руководство пользователя страница 71](http://html2.mh-extra.com/html/idex/hale-sam/hale-sam_operation-installation-maintenance-manual_3699854071.webp)
55
❑
Verify required Governor module is present, plugged into the Blue and the vehicle CAN
networks, and the COM indicator (green LED) is illuminated.
❑
Verify required Twister electronic throttle is present and connected to the Green CAN net-
work. Verify no COMM LOSS messages are displayed (or popped up) on the SAM Pump
Controller or SAM Control Center SAM INFORMATION CENTER.
❑
Verify required ITL-40 (water tank level indicator) is present, connected to the Green CAN
network, and indicating the correct water tank water level.
❑
Verify SAM Pump Controller is present and plugged into the Green and the Blue CAN net-
works.
❑
Verify required SAM Control Center is present and plugged into the Green and Red CAN
networks.
❑
Verify SAM system (red tubing) is connected to vehicle air per paragraph 5.3.
(See page 47.)
❑
Verify SAM system water column sensor hose (10 feet of 3/4-in flex tubing provided) is
connected to vehicle (Refer to Technical Manual [FSG–MNL-00211].)
❑
Verify SAM system interlock wiring is connected to vehicle.
❑
Verify no SIGNAL LOST/COMM LOSS messages are displayed (or popped up) on the SAM
Control Center.
Verify optional SAM equipment, if specified, is present and correctly interconnected.
❑
Verify that if optional Navigator Pro(s) are specified, that they are present, labeled, are
plugged into the Green CAN network, and operate the associated valve.
❑
Verify that if optional master intake valve(s) (master intake valve #3 thru #5) are speci-
fied that they are present, labeled, and plugged into the Green CAN network.
❑
Verify that if more than three MIVs are specified, that master intake valve–A Plus #2
module is present, labeled, connected to the Green CAN network, and the COM indicator
(green LED) is illuminated.
❑
Verify that if the optional wireless range extender and DC-to-DC converter (converts
12 VDC to 24 VDC) is specified, that they are present and connected to a 12 VDC SAM
power source.
❑
Verify that if the optional ruggedized tablet is specified, that it is present and configured
with a secured wi-fi connection.
6.1.1
SAM Power On And Default Verifications
Power on the primer and SAM system as follows.
A.
Turn on chassis power following chassis manufacturers procedures.
B.
Verify SAM Control Center and Pump Controller displays turn on and display their
boot screens. (See Figure 18 for SAM Control Center boot screen and Figure 30
for Pump Controller boot screen.)
C.
Verify SAM Control Center display transitions to landing screen (Figure 18) and
then Auto Mode Home screen (Figure 19) when pump is placed in gear.
NOTE
If the SELECT DEVICE screen (Figure 67, page 64) is displayed, perform para-
graph 6.2.2, Reboot To GUI.