112
Table 8. SAM Operator Troubleshooting–CONTINUED
SYMPTOM
CAUSE
REMEDY
WARNINGS–CONTINUED
RH INTAKE MASTER INTAKE
VALVE MODULE LOST OPER-
ATE RH MASTER INTAKE
VALVE WITH MANUAL OVER-
RIDE KNOB
Equipment failure
Perform valve physical override
(See paragraph 6.3.6.1, pg. 103)
NOTE
Report incident to maintenance
SAM SCREEN SIGNAL LOST
OPERATE IN MANUAL MODE
OR USE REMOTE SCREEN
Equipment failure
If equipped with auxiliary SAM
Control Center, use auxiliary
If equipped with tablet option, op-
erate from tablet
THE TABLET ONLY OPERATES
FROM THE SAM CONTROL CENTER
LOCATED IN THE OPERATORS
PANEL, IF THAT SCREEN FAILS,
THE TABLET MAY NOT CONTROL
THE APPARATUS
If SAM Control Center is no longer
functioning, press idle button to
enter Manual Mode and set pump
pressure using Twister
SENSOR MODULE NOT
FOUND PUMP NOT PRO-
TECTED FROM OVERHEAT
Equipment failure
NOTE
Water is typically circulated au-
tomatically thru the onboard
water tank; however, a small
tank may become overheated
Manually open tank fill and/or
tank-to-pump valve [open valve(s)
more if already partially open]
Flow water to atmosphere
(ground); ensure an intake (exter-
nal water source) is open and
slightly open a discharge
NOTE
Report incident to maintenance
TANK-TO-PUMP COM LOST
USE MANUAL OVERRIDE
Equipment failure
Perform valve physical override
(See paragraph 6.3.6.2, pg. 104)
NOTE
Report incident to maintenance
WARNING LOW FOAM TANK
Operator error
Foam tank empty
Refill foam tank
Equipment failure
EZ Fill failure
NOTE
Report incident to maintenance