IDEC SmartRelay Manual
205
IDEC SmartRelay functions
4.4 Special functions list - SF
4.4.26
Softkey
Short description
This special function has the effect of a mechanical pushbutton or switch.
Factory setting
The default parameter setting is switching action.
Timing diagram
Symbol in
IDEC SmartRelay
iring
Description
Input En
Output is set with a 0 to 1 transition of the signal at
input En (Enable), and if Switch On was confirmed
in parameter assignment mode.
Parameter
Programming mode:
Selecting the function for pushbutton action for the
duration of one cycle, or for switching action.
Start: on or off state, initialized at the first start of the
program if retentivity is disabled.
Retentivity:
/ no retentivity
R the status is retentive.
Parameter assignment mode (RUN mode):
Switch: switches the momentary pushbutton (switch)
on or off.
Output
Switches on if En 1 and Switch On was confirmed
with O .
4
(Q
3DU
6RIWNH\
4
(Q
6ZLWFK