While the system program is downloaded to the MicroSmart, the RUN LED on the CPU module flashes.
After the system program download, the MicroSmart remains stopped. To start the MicroSmart, select
Online
>
Start
from the
WindLDR menu bar. The MicroSmart can also be started using HMI module. See page 2-80 (Basic Vol.).
The user program stored in the MicroSmart before downloading the system program remains and is executed when the MicroSmart
is restarted. A user program execution error may occur if an older system program is downloaded to the MicroSmart.
In the event that the system update process fails, the RUN LED on the FC5A MicroSmart may keep flashing continuously. In such
cases, turn the FC5A MicroSmart off and on, and then retry the update procedure from the step 1. If the RUN LED continues flashing
after the power is turned off and on, a communication error dialog box is displayed before the step 4. In such cases, perform the fol-
lowing two steps.
1) A communication error dialog box is displayed. Click
Cancel
.
2) A dialog box prompting you to check the RUN LED status is displayed. Click
Yes
.
Getting the Latest Version of the System Program
When you install or upgrade to the latest version of Automation Organizer, the latest system programs are also installed
along with the software.