6: D
EVICE
A
DDRESSES
6-20
FC5A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y-B1268
Note:
Devices for high and low words can be swapped on upgraded CPU modules with system program version 110 or higher. See page
5-47.
Special Data Register for HMI Module
D8068
HMI Module Initial Screen Selection
Power-up
5-62
Special Data Registers for Data Link Master/Slave Stations and Modbus Master Station
Device Address
Description
Updated
See Page
D8063
— Reserved (All-in-one type CPU) —
Frequency Measurement Value I3 Low Word (Slim type CPU)
Every scan
5-30
D8064
Frequency Measurement Value I4 (All-in-one type CPU)
Frequency Measurement Value I4 High Word (Slim type CPU)
Every scan
5-30
D8065
— Reserved (All-in-one type CPU) —
Frequency Measurement Value I4 Low Word (Slim type CPU)
Every scan
5-30
D8066
Frequency Measurement Value I5 (All-in-one type CPU)
Frequency Measurement Value I7 High Word (Slim type CPU)
Every scan
5-30
D8067
— Reserved (All-in-one type CPU) —
Frequency Measurement Value I7 Low Word (Slim type CPU)
Every scan
5-30
D8069
Slave Station 1
Communication Error (at Master Station)
Slave Station
Communication Error (at Slave Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8070
Slave Station 2
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8071
Slave Station 3
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8072
Slave Station 4
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8073
Slave Station 5
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8074
Slave Station 6
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8075
Slave Station 7
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8076
Slave Station 8
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8077
Slave Station 9
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8078
Slave Station 10
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8079
Slave Station 11
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8080
Slave Station 12
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8081
Slave Station 13
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8082
Slave Station 14
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8083
Slave Station 15
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
D8084
Slave Station 16
Communication Error (at Master Station)
Error station number and error code (at Modbus Master)
When error occurred
11-4, 12-14
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]