Related Commands:
Examples:
Command: ~02D02
Response: !02
Sets the PIR Relay Output signal for module 02 to 02, which denotes that the PIR
Relay Output channel is in inactive mode, and returns a response indicating that the
command was valid.
Command: ~02D
Response: !0202
Reads the status of the Relay Output signal for module 02 and returns a response
indicating that the command was valid, with a value of 02, which denotes that the PIR
Relay Output channel is in inactive mode.