PIR-130-AC/DC User Manual
Ver. 1.4.0, 2020/07/28
36/93
2.9
@AADI
Description:
This command is used to read the current status of the PIR Relay Output channel and PIR active
status on a specified module.
Syntax:
@AA[CHKSUM](CR)
@
Delimiter character
AA
The address of the module to be read in hexadecimal format (00 to FF)
DI
The command to read the current status of the PIR Relay Output channel and PIR
active status
Response:
Valid Command:
>(Data)[CHKSUM](CR)
Invalid Command:
?AA[CHKSUM](CR)
>
Delimiter character to indicate that the command was valid
?
Delimiter character to indicate that the command was invalid
AA
The address of the responding module in hexadecimal format (00 to FF)
S
High temperature alarm enable status, 0=alarm disable, 1=momentary alarm enabled,
2=latch alarm enabled.
OO
The status of the PIR Relay Output channel represented by a two-digit hexadecimal
value. 00: PIR Relay Output is inactive; 01: PIR Relay Output is active.
II
The PIR active status represented by a two-digit hexadecimal value. 00: The status of
the PIR is active; 01: The status of the PIR is inactive.
There will be no response if the command syntax is incorrect, there is a communication error, or
there is no module with the specified address.
Examples:
Command: @02DI
Response: >0100101
Reads the status of the PIR Relay Output channel for module 02 and returns a
response indicating that the command was valid, and that both the PIR Relay Output
channel and the status of the PIR are active.
Содержание PIR-130-AC
Страница 1: ...PIR 130 AC DC User Manual Ver 1 4 0 2020 07 28 1 93 PIR 130 AC DC User Manual ...
Страница 11: ...PIR 130 AC DC User Manual Ver 1 4 0 2020 07 28 11 93 1 4 Wiring Connections PIR 130 AC PIR 130 DC ...
Страница 15: ...PIR 130 AC DC User Manual Ver 1 4 0 2020 07 28 15 93 1 7 Hardware Overview Front Rear ...
Страница 37: ...PIR 130 AC DC User Manual Ver 1 4 0 2020 07 28 37 93 Related Commands Section 2 4 AA6 ...