CAN-8123/CAN-8223/CAN-8423 user’s manual (Revision 3.00, May/22/2009) ------
58
4.6 CAN-8423 Configuration (On-line mode)
Before using the CAN Slave utility in the On-line mode of the CAN-8423,
please make sure that all connections are ready, from the CAN-8423 to your
PC via COM port. The architecture figure is displayed in the following. Take the
following application as an example, the CAN-8423 and slot modules, I-87057,
I-87057, I-87024 and I-87017 are inserted in the slot 0, 1, 2, 3 respectively.
Step 1: To turn off the CAN-8423 is the beginning. Then, users can set the
“Baud” rotary switch of CAN-8423 to 9. Then, turn on the CAN-8423.
8
7
0
C
4
2
1
F
D
B
9
5
3
A
6
E
BAUD
Step 2: Please use the “Baud” rotary switch again to set the baud rate for the
CAN-8423, i.e. if users want to set baud rate in 1000Kbps, they have to adjust
the “Baud” rotary switch to 7.
8
7
0
C
4
2
1
F
D
B
9
5
3
A
6
E
BAUD
Step 3: To execute the CAN_SL.exe file, and to display the figure, users have