CAN-8123/CAN-8223/CAN-8423 user’s manual (Revision 3.00, May/22/2009) ------
131
Step 40. According to the purposes, users have to fill the DI8~DI15 of the
I-8053 and AI0 of the I-87017 into the index 0x1A05 with sub-index 02 and 03
respectively.
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 1 0 0 0 0 0 0 0 0 1
0
8
23 05 1A
02
08 02 00
60
SDO client
SDO server
(CAN-8123/CAN-8223/
CAN-8423)
ccs
: 1
n
: 0
e
: 1
s
: 1
m
: 05 1A 02
d
: 08 02 00 60
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 0 1 1 1 0 1 1 1 0 1
0
8
60 05 1A
02
00 00 00
00
SDO client
SDO server
(CAN-8123/CAN-8223/
CAN-8423)
scs
: 3
m
: 05 1A 02