CAN-8123/CAN-8223/CAN-8423 user’s manual (Revision 3.00, May/22/2009) ------
152
cs
: NMT command specified
130: Reset_Communication
Node ID
: the node ID of the NMT slave device
Module Control Protocol Example
If the CAN-8423 node ID is set to 5 as an example, the following steps
would be…
Step1. Turn off the CAN-8423.
Step2. Then, turn it on. After the initialization, the CAN-8423 will automatically
enter the Pre_Operational state. Users will note the RUN LED flashing twice
per second.
Step3. Users can send the NMT module control protocol, and control the
CAN-8423 to enter the operational state.
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
0 0 0 0 0 0 0 0 0 0 0
0
8
01 05 00
00
00 00 00
00
NMT master
NMT slave
(CAN-8123/CAN-8223/
CAN-8423)
cs
: 1
Node ID
: 5