CAN-8123/CAN-8223/CAN-8423 user’s manual (Revision 3.00, May/22/2009) ------
169
1h
COB-ID used by PDO (Rx)
UNSIGNED 32
RW
400h+Node-ID
2h
transmission type
UNSIGNED 8
RW
FFh
1403h
0h largest sub-index supported for
“receive PDO parameter”
UNSIGNED 8
RO
5
1h
COB-ID used by PDO (Rx)
UNSIGNED 32
RW
500h+Node-ID
2h
transmission type
UNSIGNED 8
RW
FFh
1404h
0h largest sub-index supported for
“receive PDO parameter”
UNSIGNED 8
RO
5
1h
COB-ID used by PDO (Rx)
UNSIGNED 32
RW
80000000h
2h
transmission type
UNSIGNED 8
RW
FFh
... ...
...
...
...
...
140Fh
0h largest sub-index supported for
“receive PDO parameter”
UNSIGNED 8
RO
5
1h
COB-ID used by PDO (Rx)
UNSIGNED 32
RW
8000 0000h
2h
transmission type
UNSIGNED 8
RW
FFh
RxPDO Mapping Communication Entries
Idx Sidx
Description
Type
Attr
Default
1600h
0h largest sub-index supported for
“receive PDO mapping”
UNSIGNED 8
RO
8
1h
write digital output 1h to 8h
UNSIGNED 8
RW
6200 0108h
2h
write digital output 9h to 10h
UNSIGNED 8
RW
6200 0208h
3h
write digital output 11h to 18h
UNSIGNED 8
RW
6200 0308h
4h
write digital output 19h to 20h
UNSIGNED 8
RW
6200 0408h
5h
write digital output 11h to 28h
UNSIGNED 8
RW
6200 0508h
6h
write digital output 19h to 30h
UNSIGNED 8
RW
6200 0608h
7h
write digital output 11h to 40h
UNSIGNED 8
RW
6200 0708h
8h
write digital output 19h to 48h
UNSIGNED 8
RW
6200 0808h
1601h
0h largest sub-index supported for
“receive PDO mapping”
UNSIGNED 8
RO
4
1h
write analog output 1h
UNSIGNED 16
RW
6411 0110h
2h
write analog output 2h
UNSIGNED 16
RW
6411 0210h
3h
write analog output 3h
UNSIGNED 16
RW
6411 0310h
4h
write analog output 4h
UNSIGNED 16
RW
6411 0410h
1602h
0h largest sub-index supported for
“receive PDO mapping”
UNSIGNED 8
RO
4