Step 7. When the reception is confirmed, the CAN-8423 will send a message
to enter the End SDO Block Upload protocol.
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 0 1 1 0 0 0 0 0 0 1
0
8
D5 00 00 00 00 00 00 00
SDO client
SDO server
(CAN-8x23)
scs
: 6
n
: 5
This value means the invalid data in the last segment are from
[8-5] to 7, i.e. only the first 3 bytes are valid.
ss
: 1
crc
: 00
00
Step 8. Users will send a message to finish the End SDO Block Upload
protocol.
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 1 0 0 0 0 0 0 0 0 1
0
8
A1 00 00 00 00 00 00 00
SDO client
SDO server
(CAN-8x23)
ccs
: 5
cs
: 1