I-7550E PROFIBUS/Ethernet Converter User Manual
(Version 1.00, June/2014)
PAGE: 89
Byte 9 should be zero.
Input Total Index is too large!
When I-7550E receive the
Ethernet data, and it can’t be
partitioned in 255. Please
increase PROFIBUS input IO
length or decrease data length.
Mode2:Check Connection ID
error
In mode 2, the Byte 2 is error
value.
Figure 95 Error Message INFO
(3)
DIAGNOSTIC INFO
:
When PROFIBUS state is online, this page will shows the diagnostic
messages of I-7550E, as shown in
Figure 96
.
Figure 96 Diagnostic info
(4)
FIFO BUFFER INFO
:
This page shows the FIFO usage information as shown in
Figure 97
.
It includes every connection ID FIFO usage status and PROFIBUS
FIFO status. It also will show up the status of each connection.