STC; Setting of Immunity to Air Bubbles
■
(MENU
w
STC)
To set the immunity to air bubbles in the sea sur-
faces so as to improve the image legibility, proceed
as follows. (Default: 0)
Push [MENU], and rotate [DIAL] until the “STC”
q
menu becomes highlighted.
Push [ENTER] then rotate [DIAL] until the desired
w
STC for the frequency, “50kHz STC...” or “200kHz
STC...” become highlighted.
• Push [CLEAR] to return to the previous menu.
Push [ENTER] to enter the STC adjustment mode,
e
then rotate [DIAL] to adjust to the desired immunity
level.
r
Push [ENTER] to exit the “STC” menu.
MENU
WPT
FOCUS
LAYOUT
MOB
CLEAR
SUB
BRILL
RANGE
[DIAL]/
[ENTER]
[CLEAR]
[MENU]
<STC menu>
• STC adjustment readout
This setting set the STC effective from 1, 2 or 3.
1 : STC setting is effective for shallow depth area.
2 : STC setting is effective for both shallow and deep
depth area.
3 : STC setting is effective for deep depth area.