147
11
SCANS
■
Scan set mode
The scan speed, Scan Resume function and [MAIN
DIAL] scan function can be set in the Scan Set mode.
q
Push [MENU] one or more times to display the “M2”
screen (Menu 2).
w
Push [SCAN](F-1) to display the “SCAN” screen.
e
Push [SET](F-5) to enter the Scan Set mode.
r
Push [
Y
](F-1) or [
Z
](F-2) to select the desired
item.
t
Rotate [MAIN DIAL] to select the desired option.
• Hold down [F-3] for 1 second to reset to the default
value.
y
Push [MENU] to save, and return to the “SCAN”
screen.
u
Push [MENU] again to return to the “M2” screen
(Menu 2).
[SET]
[SCAN]/[
∫
]
[MENU]
[F-3]
[MAIN DIAL]
[
√
]
SCAN
M E M
S W R
TCON
V S C
M 2
P R O
∂
F
SPAN
S E T
F I N
SCAN
PROG:P1
∂
F
:
±
1 0 k
Ú
SCAN Speed
Ù
1
HIGH
S E T
Ú
SCAN Resume
Ù
2
O N
S E T
Ú
MAIN DIAL (SCAN)
Ù
3
U p / D o w n
S E T
SCAN Speed
1.
(Default: HIGH)
Select the desired scan speed between high and low.
• HIGH : The scan is faster.
• LOW
: The scan is slower.
SCAN Resume
2.
(Default: ON)
Set the Scan Resume function ON or OFF.
• ON : When a signal is detected, the scan pauses for
10 seconds, then resumes. When a signal dis-
appears, the scan resumes 2 seconds later.
• OFF : When a signal is detected, the scan is can
-
celled.
MAIN DIAL (SCAN)
3.
(Default: Up/Down)
Select how the [MAIN DIAL] functions, during a scan.
• OFF
: Rotating [MAIN DIAL] cancels the scan.
• Up/Down : Rotating [MAIN DIAL] changes the scan
-
ning direction.
Push
Push
Push
Push