27
Instruction Manual C200
d)
Angle measurement :
Angle =
Angle = 0.5
*
P1 – 0.5
*
P2 – 0.5
*
P3 + 0.5
*
P4
P1
0.5
P2
- 0.5
P3
- 0.5
P4
0.5
P5
off
P6
off
P7
off
P8
off
Note :
If all measuring inputs are switched off, the numeric display of the column gauge will indi-
cate
‘Err. 01’
because measurement operation is not possible.
If the same measuring input is assigned to several gauges in the operating mode
Gauge
selection by auto recognition
, the numeric display of the column gauge will indicate
‘Err.
08’
.
If a measurement value would change for a measuring input that is assigned several times,
the measurement values for several gauges would change at the same time, and an automatic
gauge selection would consequently not be possible.
In addition to the static measuring mode, the
C200
column gauge also has several dynamic measuring
modes available. Each of the 8 gauges (
C1
to
C8
) can be assigned its own measuring mode without any
restriction.
Turn the encoder to select the
MEASURING MODE
and then push the encoder button to access the
menu. In the display
“StAtic”
will flash. Turn the encoder to switch from the static to the dynamic
measuring modes (
flashing display:
“dyn”
)
and vice versa.
After selecting the required measuring mode (
static / dynamic
), push the encoder button to confirm the
selected mode.
In the dynamic measuring mode, you can select the particular mode by turning the encoder. Then push
the encoder button to confirm the selected mode.
Min
Æ
Minimum
Max
Æ
Maximum
TIR
Æ
Max - Min
Mean
Æ
( Max + Min ) / 2
Bore
Æ
Special bore mode. Zero adjustment is performed in this mode by
applying the most recent dynamic measurement result
P1 - P2 _ P3 - P4
2 2