2.3.4 Fitting IMBus modules into the C200 column gauge
Once the IMBus modules have been connected, they are slid into the
C200
column section as a
package from the top and are then screwed to the column base using both cross-recessed screws.
!!! Do not overtighten screws !!!
If modules have already been fitted into the
C200
column and additional modules are to be in-
stalled, then all previously fitted modules must be removed first.
Loosening and removing previously fitted IMBus modules :
The IMBus modules are screwed to the
C200
base by means of 2 screws. At first both cross-
recessed screws must be loosened by using a suitable screwdriver in order to remove the fitted
modules. Two lock washers keep the screws in place and they remain in the
C200
base. The
base does
not need to be removed
. Once both screws have been completely loosened, the
IMBus modules can be slid to the top of the column and removed from it.
After removal of the initially fitted modules, additional modules
can be added. Afterwards the complete module package can be
slid into the
C200
column section. Finally the module package
is screwed to the column base.
2.3.5 Fitting of C200 column cover.
Place the column cover on top of the C200 and fix with two Allen screws ( M3 x 8).
!!! Do not overtighten screws !!!
Remove
IMBus modules
Loosen screws