Table
39.
DS4800
Symptom-to-FRU
index
(continued)
Problem
indicator
Component
Possible
cause
Possible
solutions
One
or
more
Green
LEDs
off
Controller
Cache
LED
off
Caching
is
not
enabled
or
was
disabled
because:
v
The
cache
memory
in
controllers
A
and
B
is
mismatched.
v
The
battery
is
charging
or
performing
a
diagnostic
test.
v
One
of
the
cache
backup
battery
packs
has
failed.
Or,
there
are
no
I/Os
being
sent
to
the
DS4800.
Enable
write-caching
using
the
DS4000
Storage
Manager
client
program.
Or:
v
Use
the
DS4000
storage
manager
client
program
to
verify
the
cache
memory
for
both
controllers.
v
The
DS4800
performs
battery
diagnostic
tests
and
recharges
every
25
hours.
Write
caching
is
disabled
during
the
test
and
will
be
enabled
automatically
after
the
test
completes.
The
test
duration
time
varies
depending
on
the
recharging
requirement,
but
the
duration
should
be
less
than
15
minutes.
v
Replace
the
failing
battery.
If
there
are
no
I/Os
being
sent
to
the
DS4800,
generate
I/Os
to
send
to
the
DS4800.
Battery
LED
off
and
power
supply
and
fan
unit
Power
LED
off
The
battery
is
missing.
Verify
that
the
battery
is
missing.
All
DS4800s
are
shipped
with
both
cache
battery
packs
installed.
Call
IBM
support
if
a
cache
battery
pack
is
missing
and
you
did
not
remove
any
of
the
cache
battery
packs
from
the
DS4800.
L1
and
L2
(Link
Speed)
LEDs
for
a
host
port
Fibre
channel
cable
is
not
attached
to
the
DS4800
host
port
or
the
FC
device
that
should
be
connected
to
this
DS4800
host
port.
Connect
the
fibre
channel
cable
to
the
enclosure
port;
check
other
connections.
No
FC
signal
detected.
Reattach
the
SFPs
and
fibre-channel
cables.
Verify
that
the
fibre
channel
cables
are
in
good
condition
and
that
there
are
no
cable
management
issues
(such
as
using
plastic
ties
to
wrap
the
cables
or
bending
the
cable
loops
to
less
than
1.5
inches).
Verify
the
SFPs
are
working
properly.
Use
the
wrap-plug
coupler
kit
that
ships
with
the
DS4800
and
the
wrap-plug
instructions
in
the
DS4000
Problem
Determination
Guide
.
Replace
input
and
output
SFPs
or
cables
as
necessary.
L1
and
L2
(Link
Speed)
LEDs
of
drive
port
SFP
module
failure
or
SFP
module
not
seated
properly.
Reseat
the
SFP.
Verify
the
SFPs
are
working
properly.
Use
the
wrap-plug
coupler
kit
that
ships
with
the
DS4800
and
the
wrap-plug
instructions
in
the
DS4000
Problem
Determination
Guide
.
Replace
SFPs
as
necessary.
172
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...