Use
the
following
procedure
to
replace
a
power
supply
and
fan
unit.
Each
power
supply
and
fan
unit
contains
a
power
supply,
cooling
fan,
battery
charger,
and
temperature
sensor.
If
any
of
these
components
fail,
you
must
replace
power
supply
and
fan
unit.
The
power
supply,
fan,
battery
charger,
and
temperature
sensor
are
not
individually
replaceable
components
within
the
power
supply
and
fan
unit.
Statement
8:
CAUTION:
Never
remove
the
cover
on
a
power
supply
and
fan
unit
or
any
part
that
has
the
following
label
attached.
Hazardous
voltage,
current,
and
energy
levels
are
present
inside
any
component
that
has
this
label
attached.
There
are
no
serviceable
parts
inside
these
components.
If
you
suspect
a
problem
with
one
of
these
parts,
contact
a
service
technician.
1.
Use
the
DS4000
Storage
Manager
client
software
to
a
storage
subsystem
profile.
2.
Locate
the
storage
subsystem
that
contains
the
failed
power
supply
and
fan
unit
by
checking
the
Overall
DS4800
Configuration
Needs
Attention
LED
on
the
front
bezel
of
the
storage
subsystem.
shows
the
location
of
the
Overall
DS4800
Configuration
Needs
Attention
LED
on
the
front
bezel.)
3.
Remove
the
front
bezel
by
grasping
the
sides
and
pulling
the
cover
toward
you.
4.
Locate
the
failed
power
supply
and
fan
unit
by
checking
that
the
power
supply
and
fan
unit
Needs
Attention
LED
that
is
turned
on.
Power LED
Overall DS4800 Configuration
Needs Attention LED
Locate/Identify LED
ds48005
Figure
91.
Overall
DS4800
Configuration
Needs
Attention
LED
on
the
DS4800
front
bezel
Chapter
5.
Replacing
components
153
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...