9.
Reset
the
circuit
breaker
that
tripped
by
pressing
down
with
the
stylus
on
the
rocker
switch.
10.
Slide
the
controller
into
the
storage
subsystem
chassis.
a.
Holding
both
levers,
slowly
push
the
controller
until
the
notches
in
both
the
left
and
right
levers
are
aligned
with
the
pins
on
the
DS4800
enclosure
so
that
the
controller
is
pulled
evenly
into
the
DS4800
storage
subsystem
chassis,
ensuring
full
electrical
connection
contact
on
all
interface
pins.
Attention:
Verify
that
the
controller
does
not
snag
any
other
DS4800
cables
when
you
slide
it
into
the
controller
bay.
b.
Press
the
controller
fully
into
the
slot,
engaging
the
pins
on
the
enclosure.
c.
Hold
open
both
latches
and
push
both
left
and
right
levers
simultaneously
to
the
closed
position.
Release
the
latches.
When
you
release
the
latches,
you
should
hear
both
latches
snap
over
the
levers,
indicating
that
the
component
is
locked
in
place.
11.
If
you
removed
the
interface
cables,
reconnect
all
host
interface
cables
and
drive
interface
cables,
including
the
SFP
modules.
12.
Wait
up
to
5
minutes
for
the
DS4000
Storage
Manager
client
software
to
recognize
the
controller.
13.
Complete
any
remaining
Recovery
Guru
procedures
for
controller
replacement,
if
needed.
14.
Based
on
the
Host
Channel
Speed,
Drive
Channel
Speed,
and
Needs
Attention
LED
status,
proceed
to
one
of
the
following
steps:
v
All
channel
speed
LEDs
are
on
and
the
Needs
Attention
LED
is
off
–
Go
to
step
v
All
channel
speed
LEDs
are
off
or
the
Needs
Attention
LED
is
on
–
Verify
the
controller
has
been
installed
correctly.
Remove
and
reinstall
the
controller.
Go
to
step
Note:
If
a
host
channel
or
drive
channel
does
not
have
a
cable
connected,
the
channel
speed
LEDs
are
not
illuminated.
15.
Did
this
action
correct
the
problem?
v
Yes
–
Go
to
step
v
No
–
If
the
problem
has
not
been
fixed,
contact
your
IBM
service
representative.
16.
Remove
the
antistatic
protection.
17.
Install
the
front
bezel
by
aligning
the
pins
on
the
storage
subsystem
chassis
with
the
spring-steel
retainers
on
the
cover
and
then
pressing
the
cover
toward
the
chassis
until
the
pins
snap
into
place.
18.
Using
the
Enterprise
Management
window,
view
the
status
of
the
storage
subsystems.
Do
any
storage
subsystems
indicate
Needs
Attention?
v
Yes
–
Go
to
step
v
No
–
All
components
display
Optimal
status.
You
are
finished
with
this
procedure.
19.
Use
the
Subsystem
Management
window
to
check
the
status
of
all
storage
subsystems
in
the
configuration.
20.
Do
any
storage
subsystems
have
a
Overall
DS4800
Configuration
Needs
Attention
status?
a.
Yes
–
Select
the
Recovery
Guru
toolbar
button
in
the
Subsystem
Management
window,
and
complete
the
recovery
procedure.
If
the
problem
persists,
contact
your
IBM
service
representative.
136
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...