Table
24.
Description
of
Figure
55
(continued)
Number
Description
10
EXP810
enclosure
6
11
EXP810
enclosure
7
12
EXP710
enclosure
1
13
EXP710
enclosure
2
14
EXP710
enclosure
3
15
EXP710
enclosure
4
16
EXP710
enclosure
5
17
EXP710
enclosure
6
18
EXP710
enclosure
7
19
EXP710
enclosure
8
1.
Make
all
connections
from
the
left
ESMs
to
the
right
ESMs
in
the
expansion
enclosures,
as
indicated
by
21
,
23
,
22
,
and
24
.
2.
To
create
drive
channel
1,
after
connecting
enclosures
1,
2,
3,
and
4
together
(
21
),
connect
drive
port
4
of
controller
A
(
4A
)
to
EXP810
enclosures
1
(
5
),
2
(
6
),
3
(
7
),
and
4
(
8
);
then,
connect
drive
port
1
of
controller
B
(
1B
)
to
enclosures
4
(
8
),
3
(
7
),
2
(
6
),
and
1
(
5
).
3.
To
create
drive
channel
3,
after
connecting
enclosures
5,
6,
and
7
together
(
23
),
connect
drive
port
3
of
controller
A
(
3A
)
to
EXP810
enclosures
5
(
9
),
6
(
10
),
and
7
(
11
);
then,
connect
port
2
of
controller
B
(
2B
)
to
enclosures
7
(
11
),
6
(
10
),
and
5
(
9
).
4.
To
create
drive
channel
2,
after
connecting
EXP710
enclosures
8,
9,
10,
and
11
together
(
22
),
connect
drive
port
2
of
controller
A
(
2A
)
to
enclosures
8
(
12
),
9
(
13
),
10
(
14
),
and
11
(
15
);
then,
connect
drive
port
3
of
controller
B
(
3B
)
to
enclosures
11
(
15
),
10
(
14
),
9
(
13
),
and
8
(
12
).
5.
To
create
drive
channel
4,
after
connecting
EXP710
enclosures
12
(
16
),
13
(
17
),
14
(
18
),
and
15
(
19
)
together
(
24
),
connect
drive
port
1
of
controller
A
(
1A
)
to
enclosures
12
(
16
),
13
(
17
),
14
(
18
),
and
15
(
19
);
then,
connect
drive
port
4
of
controller
B
(
4B
)
to
enclosures
15
(
19
),
14
(
18
),
13
(
17
),
and
12
(
16
).
One
DS4800
to
two
or
more
storage
expansion
enclosures
in
a
mixed
environment
When
intermixing
EXP100s,
EXP710s,
and
EXP810s
in
a
DS4800
storage
subsystem
configuration,
if
it
is
not
possible
to
cable
each
group
of
enclosures
by
model
type
(EXP100s,
EXP710s,
and
EXP810s)
in
a
separate
redundant
drive
loop
pair
or
behind
each
port
of
the
dual-ported
redundant
drive
channel
pair,
group
them
so
that
EXP810s
are
between
EXP100s
and
EXP710s.
In
addition,
when
an
EXP100
is
the
first
storage
expansion
enclosure
cabled
directly
to
the
storage
subsystem's
controller
drive
port,
follow
these
rules:
v
Cable
from
the
storage
subsystem
controller
drive
port
to
the
OUT
port
on
the
left
ESM
(ESM
A)
of
the
EXP100.
Note:
This
is
a
change
from
previous
cabling
recommendations
where
you
cabled
from
the
controller
drive
port
to
the
IN
port
on
the
left
ESM
(ESM
A)
of
the
EXP100.
v
If
an
EXP100
follows
the
initial
EXP100,
cable
from
the
IN
port
on
the
left
ESM
(ESM
A)
of
the
first
EXP100
to
the
OUT
port
on
the
left
ESM
of
the
next
Chapter
3.
Cabling
the
storage
subsystem
81
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...