![IBM TotalStorage DS4800 Скачать руководство пользователя страница 115](http://html2.mh-extra.com/html/ibm/totalstorage-ds4800/totalstorage-ds4800_installation-user-and-maintenance-manual_4105020115.webp)
Attention:
When
connecting
storage
expansion
enclosures,
it
is
recommended
that
you
use
the
tens
digit
(x10)
enclosure
ID
setting
to
distinguish
different
redundant
loops
and
use
the
ones
digit
(x1)
enclosure
ID
setting
to
distinguish
storage
expansion
enclosures
IDs
within
a
redundant
loop.
If
you
do
not
set
the
single
digit
value
of
the
enclosure
IDs
to
be
unique
among
storage
expansion
enclosures
(including
the
DS4000
storage
subsystem
with
drives
installed)
in
a
redundant
drive
channel/loop
pair,
then
drive
loop
errors
might
be
randomly
posted
in
the
DS4000
subsystem
Major
Event
Log
(MEL)
when
you
intermix
different
types
of
storage
expansion
enclosures
in
a
redundant
drive
loop
pair
(such
as
an
EXP100
with
an
EXP810).
For
example,
in
a
DS4800
configuration
with
16
storage
expansion
enclosures
distributed
equally
behind
the
four
controller
drive
ports,
the
recommended
enclosure
ID
settings
for
the
enclosures
are
shown
in
Table
28.
Recommended
enclosure
ID
settings
scheme
Enclosure
ID
behind
the
first
controller
drive
port
Enclosure
ID
behind
the
second
controller
drive
port
Enclosure
ID
behind
the
third
controller
drive
port
Enclosure
ID
behind
the
fourth
controller
drive
port
Enclosure
1
00
04
10
14
Enclosure
2
01
05
11
15
Enclosure
3
02
06
12
16
Enclosure
4
03
07
13
17
The
DS4800
normally
ships
with
an
enclosure
ID
outside
the
range
of
00–77.
However,
if
your
DS4800
enclosure
ID
was
set
to
a
value
within
the
range
of
00–77,
it
may
be
in
conflict
with
the
enclosure
ID
of
one
of
the
EXP100
or
EXP710
drive
expansion
enclosures
that
you
are
trying
to
attach
to
the
DS4800.
If
this
is
the
case,
the
amber
ID
Conflict
LED
on
the
storage
expansion
enclosure
will
light
up
after
you
power
on
the
storage
subsystem.
Give
each
storage
expansion
enclosure
in
a
redundant
drive
channel
pair
a
unique
ones
digit
(x1)
ID.
This
setting
will
enforce
hard
AL_PAs
(unchangeable
between
fibre
channel
Loop
Initializations
[LIPs])
for
the
drives
and
facilitate
drive
channel
problem
troubleshooting
in
the
event
of
an
error.
If
the
ones
digits
are
not
unique,
two
or
more
devices
will
have
the
same
hard
AL_PA.
In
such
a
case,
the
DS4800
controller
will
use
soft
AL_PAs
for
the
devices
that
have
identical
hard
AL_PAs.
The
problem
with
soft
addressing
is
that
addresses
may
change
between
LIPs.
This
possibility
increases
the
difficulty
of
troubleshooting
drive
channel
problems,
since
one
cannot
easily
ascertain
whether
the
same
device
with
a
different
address
or
a
different
device
may
be
causing
a
problem.
Connecting
hosts
to
the
DS4800
The
DS4800
supports
redundant
connections
to
up
to
four
hosts.
To
ensure
full
protection
against
the
loss
of
any
one
fibre
channel
path
from
the
host
servers
to
the
DS4800
Storage
Subsystem,
always
use
redundant
host
connections
by
connecting
each
host
to
the
appropriate
single-ported
host
channels
on
both
RAID
controllers
A
and
B.
To
connect
a
host
adapter
to
the
DS4800
RAID
controllers,
perform
the
following
steps:
Chapter
3.
Cabling
the
storage
subsystem
87
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|||||
|||||
|||||
|
|
|
|
|
|
|
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...