![IBM TotalStorage DS4800 Скачать руководство пользователя страница 156](http://html2.mh-extra.com/html/ibm/totalstorage-ds4800/totalstorage-ds4800_installation-user-and-maintenance-manual_4105020156.webp)
Table
38.
Interconnect-battery
unit
LEDs
(continued)
Legend
LED
Color
Normal
Status
Problem
Status/Procedure
2
Power
Green
LED
On
=
storage
subsystem
is
powered
on
Off
=
storage
subsystem
is
powered
off
If
the
storage
subsystem
is
powered
on
but
this
LED
remains
off,
examine
the
power
supply
and
fan
units,
the
connected
PDUs,
and
the
connected
power
circuits
for
any
of
the
following
conditions:
v
Both
power
supply
and
fan
units
are
not
turned
on.
v
A
circuit
breaker
has
tripped.
v
The
connected
PDUs
are
turned
off
or
have
been
tripped.
v
There
is
no
power
at
the
wall
circuit.
v
The
interconnect-battery
unit
is
bad.
3
Overall
DS4800
Configuration
Needs
Attention
Amber
LED
Off
On
=
A
component
in
the
storage
subsystem
configuration
has
developed
a
fault.
Inspect
the
Needs
Attention
LEDs
on
the
other
components
in
the
DS4800
Storage
Subsystem
and
in
all
connected
DS4000
storage
expansion
enclosures
to
isolate
the
fault.
However,
it
is
recommended
that
you
use
the
DS4000
Storage
Manager
Subsystem
Management
window
to
identify
the
cause
of
the
problem
and
use
the
Recovery
Guru
to
help
fix
the
problems.
Some
of
the
problems
may
not
cause
the
Needs
Attention
LED
on
the
individual
CRU
to
light,
but
they
will
cause
this
Overall
DS4800
Configuration
Needs
Attention
LED
to
light.
For
example,
a
hard
disk
drive
that
exceeds
its
PFA
errors
will
cause
this
LED
to
light,
but
the
drive
Needs
Attention
LED
for
the
individual
drive
in
the
attached
storage
expansion
enclosure
will
not
light.
See
128
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......