Adapter installation instructions
Note:
v
The instructions in this section apply to any supported adapter (for example,
network adapters).
v
The server does not support any high-definition video-out connector or stereo
connector on any add-on video adapter.
To install an adapter, complete the following steps:
1.
Read the safety information that begins on page “Safety” on page vii and the
“Installation guidelines” on page 33.
2.
Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3.
Remove the top cover (see “Removing the server top cover” on page 36).
4.
Remove the microprocessor and memory expansion tray (see “Removing the
microprocessor and memory expansion tray assembly” on page 278) or DIMM
air baffle (see “Removing the DIMM air baffle” on page 210), whichever one is
installed.
5.
Follow the cabling instructions, if any come with the adapter. Route the adapter
cables before you install the adapter. The cables should be routed through the
SAS cable guide.
6.
To install an adapter on the system board
, complete the following steps:
a.
Open the PCIe retention latch and remove the PCIe filler bracket from the
connector in which you want to install the adapter.
b.
Insert the adapter into the PCIe slot, aligning the edge connector on the
adapter with the connector on the system board. Press the edge of the
connector on the adapter
firmly
into the connector on the system board.
Make sure that the adapter snaps into the PCIe connector securely.
Attention:
Make sure that the adapter is correctly seated. An incorrectly
seated adapter might cause damage to the system board or the adapter.
c.
Close the PCIe retention latch.
d.
Skip to step 8 on page 73.
7.
To install an adapter on the PCIe riser-card assembly
, complete the following
steps:
a.
Grasp the riser-card assembly by the blue touch points and pull it up until
it disengages from the connector on the system board.
b.
Open the PCIe retention latch.
c.
Remove the PCIe filler bracket from the slot in which you want to install
the adapter.
d.
Make sure that the PCIe retention latch is in the open position.
e.
Insert the adapter into the connector on the riser-card assembly, aligning the
edge connector on the adapter with the connector on the riser card
assembly. Press the edge of the connector on the adapter
firmly
into the riser
card assembly connector. Make sure that the adapter snaps into the
connector on the riser card assembly securely.
Attention:
Make sure that the adapter is correctly seated into the riser card
assembly connector and that the riser card assembly is correctly seated into
the connector on the system board before you turn on the server. An
incorrectly seated adapter might cause damage to the system board, the
72
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Содержание System x3750 M4 Type 8733
Страница 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Страница 304: ...8x2 5 inch backplane and adapter 288 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 305: ...Cabling the combination power configuration cable to the backplanes Chapter 6 Removing and replacing components 289...
Страница 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 693: ......
Страница 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...