Removing the microprocessor air baffle
To remove the microprocessor air baffle, complete the following steps:
1.
Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 33.
2.
Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3.
Remove the top cover (see “Removing the server top cover” on page 36).
4.
Grasp the baffle by the grip points, lift it all the way up out of the slots, and
set the baffle aside.
Note:
A microprocessor air baffle must be installed whenever the two DIMM
connectors closest to the microprocessor (on the left and the right) are empty.
For example, when DIMM connectors 6 and 7 on the system board are empty,
the microprocessor air baffle must be installed on microprocessor 1. This is
applicable for all microprocessors.
Microprocessor
air baffle
Attention:
For proper cooling and airflow, replace the air baffle before you
turn on the server. Operating the server with the air baffle removed might
damage server components.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 116.
Chapter 2. Installing optional devices
39
Содержание System x3750 M4 Type 8733
Страница 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Страница 304: ...8x2 5 inch backplane and adapter 288 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 305: ...Cabling the combination power configuration cable to the backplanes Chapter 6 Removing and replacing components 289...
Страница 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 693: ......
Страница 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...