806f050c-2581ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation:
IMM has detected that the Memory Logging Limit has been Reached.
Severity:
Warning
Alert Category:
Warning - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0144
SNMP Trap ID:
43
Automatically notify Support:
Yes
User response:
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f050d-0400ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation:
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0401ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation:
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drive that is indicated by a lit status LED.
806f050c-2581ffff • 806f050d-0401ffff
490
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Содержание System x3750 M4 Type 8733
Страница 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Страница 304: ...8x2 5 inch backplane and adapter 288 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 305: ...Cabling the combination power configuration cable to the backplanes Chapter 6 Removing and replacing components 289...
Страница 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 693: ......
Страница 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...