Installing the 8x2.5-inch hot-swap drive backplane
SAS signal
connector
Configuration
connector
SAS signal
connector
SAS power
connector
Note:
v
For more information about connecting the SAS signal cables to the drive
backplane, see “Connecting the SAS cables” on page 61).
v
You can install this drive backplane in backplane bays 1 and 2 or 3 and 4. It
cannot be installed in drive backplane bays 2 and 3. It is not supported.
v
The right-angle SAS cables that come with the backplane only connect to the
SAS signal connectors on the system board.
To install the 8x2.5-inch hot-swap drive backplane, complete the following steps:
1.
Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 33.
2.
Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3.
Remove the top cover (see “Removing the server top cover” on page 36).
4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on
page 40).
5.
Remove the microprocessor and memory expansion tray (see “Removing the
microprocessor and memory expansion tray assembly” on page 278) or DIMM
air baffle (see “Removing the DIMM air baffle” on page 210), whichever one is
installed.
6.
Open the SAS cable guide cover.
7.
If a backplane filler panels are installed in the backplane bay in which you are
installing the backplane, remove the backplane filler panels.
8.
Connect the two 10x2-pin power connectors on the combination
power/configuration cable to the backplane power connectors on the system
board. The power connector on the end of the black cable (which might be
labelled 1/3) connects to backplane connector 1 or 3 on the system board. The
power connector on the end of the gray cable (which might be labelled 2/4)
connects to backplane connector 2 or 4 on the system board. Connect the
configuration connector on the combination power/configuration cable to the
104
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Содержание System x3750 M4 Type 8733
Страница 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Страница 304: ...8x2 5 inch backplane and adapter 288 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 305: ...Cabling the combination power configuration cable to the backplanes Chapter 6 Removing and replacing components 289...
Страница 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 693: ......
Страница 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...