80070603-0701ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation:
IMM has detected Voltage Regulator Error.
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
4
Automatically notify Support:
No
User response:
v
CPU 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or CPU 1 itself
v
CPU 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or CPU 2 itself
v
DIMM 01-06 VRD: Indicates a problem with either the voltage regulator for DIMMs 1-6 or 1 or more of the
following components: DIMM1-DIMM6
v
DIMM 07-12 VRD: Indicates a problem with either the voltage regulator for DIMMs 7-12 or 1 or more of the
following components: DIMM7-DIMM12
v
DIMM 13-18 VRD: Indicates a problem with either the voltage regulator for DIMMs 13-18 or 1 or more of the
following components: DIMM13-DIMM18
v
DIMM 19-24 VRD: Indicates a problem with either the voltage regulator for DIMMs 19-24 or 1 or more of the
following components: DIMM19-DIMM24
v
MainBrd ENET VRD: Indicates a problem with either the voltage regulator for the onboard Ethernet or the 10Gb
add-in card
v
MainBrd SAS VRD: Indicates a problem with either the voltage regulator for the onboard SAS or the RAID cache
card
v
MainBrd VRD: Indicates a problem with a voltage regulator for the system board
v
System VRD: Indicates a problem with either a voltage regulator for the system board or the microprocessor and
memory expansion tray
1.
Check the IMM Web event log. This event may be a symptom of an earlier error.
2.
Depending on the error perform the following steps.
For a CPU 1 VRD or CPU 2 VRD error:
1.
Replace system board.
2.
Replace affected microprocessor.
For a DIMM 01-06 VRD, DIMM 07-12 VRD, DIMM 13-18 VRD, or DIMM 19-24 VRD error:
1.
Replace DIMM(s) associated with error.
2.
Replace system board.
For a MainBrd ENET VRD error:
1.
Replace the Dual-port 10Gb-T (copper) Ethernet Adapter or the Dual-port 10Gb SFP+ (fibre) Ethernet Adapter if
installed.
2.
Replace system board.
For a MainBrd SAS VRD error:
1.
Replace the RAID cache card if installed.
2.
Replace system board.
For a MainBrd VRD error:
1.
Replace system board.
For a System VRD error:
80070603-0701ffff
Appendix D. Integrated management module II (IMM2) error messages
425
Содержание System x3750 M4 Type 8733
Страница 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Страница 304: ...8x2 5 inch backplane and adapter 288 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 305: ...Cabling the combination power configuration cable to the backplanes Chapter 6 Removing and replacing components 289...
Страница 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Страница 693: ......
Страница 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...