3.
Enter the
configDownload
command.
switch:admin> configdownload -all
Server Name or IP Address [host]: 123.123.123.123
User Name [None]: Admin24
File Name [config.txt]: config-switch.txt
Password: xxxxxxxx
download complete
switch:admin>
4.
Reboot the device.
5.
Enter the
chassisEnable
command to enable all user ports and enable a virtual fabric-aware chassis.
Verifying correct operation of system
About this task
Complete the following steps to verify the correct operation of the device.
Procedure
1.
Log in to the device as admin.
switch:admin> login
login: admin
password: xxxxxxxx
switch:admin>
2.
Enter the
chassisShow
command to verify that airflow direction set on WWN cards matches airflow
direction for fans in fan and power supply assemblies installed in device. Airflow direction of fans
and power supplies displays as "Fan Direction" under each fan or power supply unit. System airflow
direction displays as "System Airflow" under the WWN card unit. The following example shows
mismatch of system airflow and airflow direction in installed fan and power supply.
POWER SUPPLY
Unit: 1
Power Source:
AC
Fan Direction:
Non-portside Intake
...
FAN
Unit: 2
Fan Direction:
Non-portside Intake
...
WWN
Unit: 1
System AirFlow:
Non-portside Exhaust
...
WWN
Unit: 2
System AirFlow:
Non-portside Exhaust
The WWN units should indicate "Non-portside Intake." If there is a mismatch of airflow direction,
RAS log messages will indicate a mismatch between system airflow direction and airflow direction of
fan in power supply or fan assembly refer to “Configuring airflow direction on WWN cards” on page
158 for instructions on configuring correct airflow direction on WWN cards.
3.
Enter the
slotShow -m
command and verify that all the installed cards are detected and that their
status is operational (enabled).
switch:admin> slotShow -m
Slot
Blade Type
ID
Model Name
Status
--------------------------------------------------
1
CP BLADE
175
CPX6
ENABLED
2
CP BLADE
175
CPX6
ENABLED
3
SW BLADE
178
FC32-48
ENABLED
4
SW BLADE
178
FC32-48
ENABLED
5
CORE BLADE
176
CR32-4
ENABLED
6
CORE BLADE
176
CR32-4
ENABLED
7
SW BLADE
178
FC32-48
ENABLED
8
AP BLADE
186
SX6
ENABLED
4.
Verify that the device is functioning correctly by entering
switchShow
or
switchStatusShow
.
This
switchShow
command displays the device and port status information.
Replacing the Chassis
199
Содержание SAN256B-6
Страница 6: ...vi SAN256B 6 Installation Service and User Guide...
Страница 10: ...x SAN256B 6 Installation Service and User Guide...
Страница 22: ...xxii SAN256B 6 Installation Service and User Guide...
Страница 24: ...xxiv SAN256B 6 Installation Service and User Guide...
Страница 34: ...6 SAN256B 6 Installation Service and User Guide...
Страница 72: ...44 SAN256B 6 Installation Service and User Guide...
Страница 92: ...64 SAN256B 6 Installation Service and User Guide...
Страница 108: ...80 SAN256B 6 Installation Service and User Guide...
Страница 152: ...124 SAN256B 6 Installation Service and User Guide...
Страница 162: ...134 SAN256B 6 Installation Service and User Guide...
Страница 198: ...170 SAN256B 6 Installation Service and User Guide...
Страница 206: ...178 SAN256B 6 Installation Service and User Guide...
Страница 210: ...182 SAN256B 6 Installation Service and User Guide...
Страница 214: ...186 SAN256B 6 Installation Service and User Guide...
Страница 218: ...190 SAN256B 6 Installation Service and User Guide...
Страница 258: ...230 SAN256B 6 Installation Service and User Guide...
Страница 278: ...250 SAN256B 6 Installation Service and User Guide...
Страница 286: ...258 SAN256B 6 Installation Service and User Guide...
Страница 289: ...WWN card power down replacement 156 Index 261...
Страница 290: ...262 SAN256B 6 Installation Service and User Guide...
Страница 291: ......
Страница 292: ...IBM Part Number 01JC333 Printed in USA SC27 8967 03 1P P N 01JC333...