![IBM Power System 8335-GCA Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/ibm/power-system-8335-gca/power-system-8335-gca_manual_607961050.webp)
Table 19. OEM record c0 specific log information, description, and service action for an 8335-GTB (continued)
OEM record c0 specific log
information
Description
Service action
3a2604yyyyyy
All of the fans are missing or failed
Ensure that the fan power cable and
the disk and fan signal cable are
seated properly. If the problem
persists, replace the following items,
one at a time, until the problem is
resolved:
Note:
page 121 to identify the physical
location and removal and
replacement procedure.
v
Power riser with time-of-day
battery slot
v
Fan power cable
v
Disk and fan signal cable
v
Disk drive and fan card
Table 20. OEM record c0 specific log information, description, and service action for an 8348-21C
OEM record c0 specific log
information
Description
Service action
320a01xxxxxx
Phy read failure
If you are viewing this event from
the BMC, the missing or defective
cable is now operational and no
service action is required. Otherwise,
replace the missing or failed LAN
cable that attaches the console to the
system.
320a02xxxxxx
Phy speed and duplex failure
320exxxxxxxx
OCC reset required
This event is for information only. No
service action is required.
3a0400xxxxxx
Chassis soft power off
A user initiated power off request
occurred. No service action is
required.
3a0402xxxxxx
Chassis soft reboot
3a0701xxxxxx
Request for PNOR access
This event is for information only. No
service action is required.
3a0702xxxxxx
Release of PNOR access
3a1100xxxxxx
Fan thread stopped
3a1101xxxxxx
Fan thread started
3a1503xxxxxx
Primary side boot failed
Go to “Resolving a system firmware
boot failure” on page 4.
3a1504xxxxxx
Golden side boot failed
Go to “Resolving a system firmware
boot failure” on page 4.
3a1601xxxxxx
Fan 1 failure
Replace Fan 1. Go to “8348-21C
locations” on page 133 to identify the
physical location and removal and
replacement procedure.
3a1602xxxxxx
Fan 2 failure
Replace Fan 2. Go to “8348-21C
locations” on page 133 to identify the
physical location and removal and
replacement procedure.
34
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...