If
Then
Yes:
Complete the service actions for the SEL events that require service actions.
v
If your system is an 8335-GCA or 8335-GTA, go to “Identifying a service action by using
sensor and event information for the 8335-GCA and 8335-GTA” on page 37. This ends
the procedure.
v
If your system is an 8335-GTB, go to “Identifying a service action by using sensor and
event information for the 8335-GTB” on page 57. This ends the procedure.
v
If your system is an 8348-21C, go to “Identifying a service action by using sensor and
event information for the 8348-21C” on page 78. This ends the procedure.
No:
If the boot problem persists, reload or update the system firmware image. Go to Getting
fixes and reload the system firmware with the same level of firmware or update the system
firmware with a more recent level of firmware. Then, reboot the system. This ends the
procedure.
12.
Search for processor deconfiguration SEL events that have a time stamp in close proximity to the
time stamp of the event with value OEM record c0 that sent you here. Processor deconfiguration
SEL events are displayed in the following form:
v
Processor CPU Func x | Transition to Non-recoverable | Asserted
Are processor deconfiguration events present?
If
Then
Yes:
Complete the service actions for the processor deconfiguration events.
v
If your system is an 8335-GCA or 8335-GTA, go to “Identifying a service action by using
sensor and event information for the 8335-GCA and 8335-GTA” on page 37. This ends
the procedure.
v
If your system is an 8335-GTB, go to “Identifying a service action by using sensor and
event information for the 8335-GTB” on page 57. This ends the procedure.
v
If your system is an 8348-21C, go to “Identifying a service action by using sensor and
event information for the 8348-21C” on page 78. This ends the procedure.
No:
Continue with the next step.
13.
Are there other types of SEL events that require a service action and have a time stamp in close
proximity to the time stamp of the event with value OEM record c0 that sent you here?
If
Then
Yes:
Complete the service actions for the SEL events that require service actions.
v
If your system is an 8335-GCA or 8335-GTA, go to “Identifying a service action by using
sensor and event information for the 8335-GCA and 8335-GTA” on page 37. This ends
the procedure.
v
If your system is an 8335-GTB, go to “Identifying a service action by using sensor and
event information for the 8335-GTB” on page 57. This ends the procedure.
v
If your system is an 8348-21C, go to “Identifying a service action by using sensor and
event information for the 8348-21C” on page 78. This ends the procedure.
No:
Continue with the next step.
14.
Power off the system and disconnect all AC power cords for 30 seconds. Then, reconnect the AC
power cords and power on the system. Does the system boot successfully?
If
Then
Yes:
This ends the procedure.
No:
Continue with the next step.
Beginning troubleshooting and problem analysis
7
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...