Table 7. Storage device problems and service actions
Problem
Service action
System is unable to find a storage device that is at the
front of the system
1.
If the system was recently installed, moved, serviced,
or upgraded, verify that the device is seated and
installed properly.
2.
Verify that the device is compatible with your system.
3.
Verify that all internal cables are properly seated and
are not physically damaged.
4.
Verify that the most recent firmware is installed on
the system. Otherwise, install the most recent
firmware if it is not already installed.
5.
Replace the drive.
6.
If your system is a 8348-21C, replace the system
backplane or the storage mezzanine card.
7.
Replace the cable.
8.
If you have a RAID adapter installed, replace it.
System is unable to find a storage device that is at the
rear of the system (8348-21C only)
If the system is unable to find one storage device that is
at the rear of the system, replace the following items, one
at a time until the problem is resolved:
v
Drive
v
Drive tray
v
System backplane
If the system is unable to find more than one storage
device that is at the rear of the system, replace the
following items, one at a time until the problem is
resolved:
v
Drive tray
v
System backplane
Drive stops working suddenly
1.
Verify that all internal cables are properly seated and
are not physically damaged.
2.
Check the system logs to verify whether the system
detected a problem.
3.
Replace the drive.
4.
If your system is a 8348-21C, replace the system
backplane or the storage mezzanine card.
5.
Replace the cable.
6.
If you have a RAID adapter that is installed, replace
it.
Other problems
Check the messages and resolve any other problems that
were detected. Then, test the drive again. If the drive
continues not to function, refer to the documentation for
the drive.
Identifying the location of the PCIe adapter by using the slot number
The error message provides information to help you to determine the location of the PCIe adapter.
For example, the log might contain an error message similar to the following text:
[131779.752714] EEH: PHB#0 failure detected, location: Slot5
Beginning troubleshooting and problem analysis
21
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...