If
Then
Yes:
This ends the procedure.
No:
Go to “Resolving a hardware problem” on page 12. This ends the procedure.
8.
Did the system complete the boot process successfully?
If
Then
Yes:
Continue with the next step.
No:
Continue with step 12 on page 7.
9.
Determine whether the system is booted from the user-updated level of the system firmware image
(primary side) or the manufacturing level of the system firmware image (golden side).
v
For in-band networks, enter the following command:
ipmitool sensor list | grep -i golden
v
To run the command remotely over the LAN, enter the following command:
ipmitool -I lanplus -U <username> -P <password> -H <BMC IP address or BMC hostname>
sensor list | grep -i golden
Do both of the returned records show 0x0080 in the data fields?
If
Then
Yes:
The error was temporary. No service action is required. This ends the procedure.
No:
One or both of the returned records have 0x0180 in the data fields. The system was booted
from the golden side. Continue with the next step.
10.
Search for processor deconfiguration SEL events that have a time stamp in close proximity to the
time stamp of the event with value OEM record c0 that sent you here. Processor deconfiguration
SEL events are displayed in the following form:
v
Processor CPU Func x | Transition to Non-recoverable | Asserted
Are processor deconfiguration events present?
If
Then
Yes:
Complete the service actions for the processor deconfiguration events.
v
If your system is an 8335-GCA or 8335-GTA, go to “Identifying a service action by using
sensor and event information for the 8335-GCA and 8335-GTA” on page 37. This ends
the procedure.
v
If your system is an 8335-GTB, go to “Identifying a service action by using sensor and
event information for the 8335-GTB” on page 57. This ends the procedure.
v
If your system is an 8348-21C, go to “Identifying a service action by using sensor and
event information for the 8348-21C” on page 78. This ends the procedure.
No:
Continue with the next step.
11.
Are there other types of SEL events that require a service action and have a time stamp in close
proximity to the time stamp of the event with value OEM record c0 that sent you here?
6
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...