5.
If you are removing more than one drive, repeat the steps in this procedure until all drives are
removed.
6.
If you are not installing a replacement drive, install a filler in the empty slot to ensure proper air
flow for cooling. For instructions, see“Installing a disk drive filler in the 5148-21L, 5148-22L,
8247-21L, 8247-22L, 8284-21A, or 8284-22A” on page 99.
7.
If you are installing a replacement drive as a replacement for the failed disk drive or solid-state
drive, go to “Replacing a disk drive or solid-state drive in the 5148-21L, 5148-22L, 8247-21L,
8247-22L, 8284-21A, or 8284-22A system with the power turned on in Linux” on page 91.
8.
To remove an SSD in an expanded function system, continue with the next step.
9.
Remove the front cover to access the SSD. For instructions to remove the front cover from an
expanded function system, see “Removing the front cover from a rack-mounted 5148-21L, 5148-22L,
8247-21L, 8247-22L, 8284-21A, or 8284-22A system” on page 148.
10.
To access the SSD slots, remove the perforated plate (B) covering the SSD cage as shown in
Figure 91.
11.
When the identify LED flashes, unlock the drive handle (B) by pushing the handle latch (A) in the
direction that is shown and pulling the drive handle (B) out toward you, as shown in Figure 92 on
page 91. If the handle is not all the way out, the solid-state drive cannot slide out of the system.
P8HAL516-2
B
Figure 91. Removing the SSD cage cover to access the SSD slots in an expanded function system
90
Disk drives or solid-state drives