i.
If the drive you want to replace is unprotected or in use, move the data from the drive before you
continue with this procedure. If the drive is in a RAID 0 (non-redundant RAID array), after you
move the data, delete the RAID 0 before proceeding. For SAS RAID controller information, see the
SAS RAID controllers for Linux(http://www.ibm.com/support/knowledgecenter/POWER8/
p8ebk/p8ebk_kickoff.htm).
j.
Look for the drive at the SCSI location you recorded. The drive might have a Failed status.
k.
Return to the IBM Power RAID Configuration Utility display.
l.
If you are removing a solid-state device that is on a PCIe RAID and SSD SAS adapter, go to
Removing and replacing the SAS RAID adapter(http://www.ibm.com/support/knowledgecenter/
POWER8/p8ebj/p7ebjBDRemoveReplace.htm), and complete that procedure.
m.
From the IBM Power RAID Configuration Utility display, select Work with disk unit recovery.
Press
Enter
.
n.
From the Work with Disk Unit Recovery display, select Concurrent remove device, and press
Enter
. A Concurrent Device Remove display is shown, similar to the following examples shown in
Figure 87 and Figure 88 on page 88.
Display Hardware Status
Type option, press Enter.
1=Display hardware resource information details
OPT Name
Resource Path/Address
Vendor
Product ID
Status
--- ------ -------------------------- -------- ----------------
----------------
sg23
FE
IBM
57CE001SISIOA
Operational
sg0
00-0E-01
IBM
SG9XCA2E200GEIBM
Active
sg1
00-0E-0A
IBM
SG9XCA2E200GEIBM
Active
sg2
00-0E-0B
IBM
SG9XCA2E200GEIBM
Active
sg3
00-0E-03
IBM
SG9XCA2E200GEIBM
Active
sg4
00-0E-09
IBM
SG9XCA2E200GEIBM
Active
sg5
00-0E-02
IBM
SG9XCA2E200GEIBM
Failed
sg6
00-0E-04
IBM
SG9XCA2E200GEIBM
Active
sg7
00-0C-26
IBM
5887
Active
sg8
00-0E-26
IBM
5887
Active
sg47
FE
IBM
57CE001SISIOA
Operational
sg26
00-0E-01
IBM
SG9XCA2E200GEIBM
Remote
sg27
00-0E-0A
IBM
SG9XCA2E200GEIBM
Remote
sg28
00-0E-0B
IBM
SG9XCA2E200GEIBM
Remote
More...
e=Exit
q=Cancel
r=Refresh
t=Toggle
f=PageDn
b=PageUp
Figure 86. Example Display Hardware Status
Concurrent Device Remove
Choose a single location for remove operations
1=Select
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- -----------------
U5887.001.Z065075-P1-D1
Empty
sg0
U5887.001.Z065075-P1-D2
Advanced Function SSD
Active
sg5
U5887.001.Z065075-P1-D3
Advanced Function SSD
Failed
sg3
U5887.001.Z065075-P1-D4
Advanced Function SSD
Active
sg6
U5887.001.Z065075-P1-D5
Advanced Function SSD
Active
U5887.001.Z065075-P1-D6
Empty
U5887.001.Z065075-P1-D7
Empty
U5887.001.Z065075-P1-D8
Empty
U5887.001.Z065075-P1-D9
Empty
sg4
U5887.001.Z065075-P1-D10
Advanced Function SSD
Active
sg1
U5887.001.Z065075-P1-D11
Advanced Function SSD
Active
sg2
U5887.001.Z065075-P1-D12
Advanced Function SSD
Active
Figure 87. Example Concurrent Device Remove display